USB 3.0 Compliance Test Configuration
USB 3.0 is a closed eye specification
Reference channel is embedded and CTLE is applied
USB 3.0 Reference Channels
Host Reference Channel
11” back panel is applied for device testing
Device Reference Channel
5” device channel is applied for host testing
3 Meter Reference Cable
Used for host and device (except captive devices) testing in addition to
reference channels
USB 3.0 Reference Equalizer
Attenuates the low frequency content of the signal to open the eye
Transmit Channel
CTLE
TP1
TP2